For laboratory and research use only. Not for human consumption.

20% OFFClaim

Certificates of analysis

Published Index Peptides batch records show the laboratory, task ID, report date and analytical results available for that lot. Review the linked report; a purity result alone does not confirm identity or sterility. 36 batch records are published, most recently tested 2026-08-24.

Published certificate-of-analysis records, including earlier lots. Match the report to the lot supplied.
ProductFormatBatch / lotHPLC purityContent per vialTesting laboratoryLab report numberTest dateReport and batch record
GLP-3 (RT)10mg per vialIP-RETA10-00199.627% (RP-HPLC)10.36 mg/vialJanoshik Analytical (CZ)#1010892026-01-22View COA for IP-RETA10-001 · Full batch record
GLP-3 (RT)40mg per vialIP-RETA40-00199.862% (RP-HPLC)45.34 mg/vialJanoshik Analytical (CZ)#1729312026-06-17View COA for IP-RETA40-001 · Full batch record · Earlier lot; superseded by IP-RETA40-002
BPC-15710mg per vialIP-BPC10-00199.546% (RP-HPLC)10.06 mg/vialJanoshik Analytical (CZ)#2116952026-08-05View COA for IP-BPC10-001 · Full batch record · Earlier lot; superseded by IP-BPC10-002
BPC-1575mg per vialIP-BPC5-00199.893% (RP-HPLC)5.56 mg/vialJanoshik Analytical (CZ)#1718842026-06-16View COA for IP-BPC5-001 · Full batch record
TB-50010mg per vialIP-TB10-00198.710% (RP-HPLC)10.65 mg/vialJanoshik Analytical (CZ)#2024392026-07-09View COA for IP-TB10-001 · Full batch record
GHK-Cu50mg per vialIP-GHK50-00199.768% (RP-HPLC)50.60 mg/vialJanoshik Analytical (CZ)#1653612026-06-11View COA for IP-GHK50-001 · Full batch record · Earlier lot; superseded by IP-GHK50-002
PT-14110mg per vialIP-PT10-00199.809% (RP-HPLC)9.50 mg/vialJanoshik Analytical (CZ)#1218682026-03-24View COA for IP-PT10-001 · Full batch record
Melanotan-110mg per vialIP-MT1-00199.719% (RP-HPLC)10.01 mg/vialJanoshik Analytical (CZ)#1552342026-05-28View COA for IP-MT1-001 · Full batch record · Earlier lot; superseded by IP-MT1-002
Melanotan-210mg per vialIP-MT2-00199.719% (RP-HPLC)10.01 mg/vialJanoshik Analytical (CZ)#1552342026-05-28View COA for IP-MT2-001 · Full batch record · Earlier lot; superseded by IP-MT2-002
GHK-Cu + BPC-157 + TB-500 Blend70mg per vialIP-GLOW70-001—GHK-Cu 50.70 mg · TB-500 10.76 mg · BPC-157 12.17 mgJanoshik Analytical (CZ)#1946622026-07-09View COA for IP-GLOW70-001 · Full batch record · Earlier lot; superseded by IP-GLOW70-002
BPC-157 + TB-500 Blend20mg per vialIP-BPCTB20-001—TB-500 11.14 mg · BPC-157 11.32 mgJanoshik Analytical (CZ)#1557132026-05-26View COA for IP-BPCTB20-001 · Full batch record
NAD+500mg per vialIP-NAD500-001—536.16 mg/vialJanoshik Analytical (CZ)#1218392026-03-18View COA for IP-NAD500-001 · Full batch record · Earlier lot; superseded by IP-NAD500-002
NAD+1000mg per vialIP-NAD1000-001—1072 mg/vialJanoshik Analytical (CZ)#1218392026-03-18View COA for IP-NAD1000-001 · Full batch record
BPC-15710mg per vialIP-BPC10-00299.701% (RP-HPLC)11.12 mg/vialJanoshik Analytical (CZ)#2145972026-08-24View COA for IP-BPC10-002 · Full batch record
GHK-Cu50mg per vialIP-GHK50-00299.728% (RP-HPLC)51.10 mg/vial (GHK 42.52 mg · Cu 8.58 mg)Janoshik Analytical (CZ)#1999662026-08-24View COA for IP-GHK50-002 · Full batch record
GHK-Cu + BPC-157 + TB-500 Blend70mg per vialIP-GLOW70-002—GHK-Cu 60.61 mg · BPC-157 11.99 mg · TB-500 11.41 mgJanoshik Analytical (CZ)#2145072026-08-24View COA for IP-GLOW70-002 · Full batch record
Melanotan-110mg per vialIP-MT1-00299.719% (RP-HPLC)10.65 mg/vialJanoshik Analytical (CZ)#1552342026-08-24View COA for IP-MT1-002 · Full batch record
Melanotan-210mg per vialIP-MT2-00299.887% (RP-HPLC)8.95 mg/vialJanoshik Analytical (CZ)#2175362026-08-24View COA for IP-MT2-002 · Full batch record
NAD+500mg per vialIP-NAD500-002—557.79 mg/vialJanoshik Analytical (CZ)#2145552026-08-24View COA for IP-NAD500-002 · Full batch record
GLP-3 (RT)10mg per vialIP-RETA10-00299.191% (RP-HPLC)10.74 mg/vialJanoshik Analytical (CZ)#2235312026-08-24View COA for IP-RETA10-002 · Full batch record
GLP-3 (RT)40mg per vialIP-RETA40-00299.781% (RP-HPLC)41.66 mg/vialJanoshik Analytical (CZ)#1655102026-08-24View COA for IP-RETA40-002 · Full batch record
DSIP5mg per vialIP-DSIP5-00199.203% (RP-HPLC)5.56 mg/vialJanoshik Analytical (CZ)#1252292026-08-24View COA for IP-DSIP5-001 · Full batch record
MOTS-c10mg per vialIP-MOTS10-00199.872% (RP-HPLC)11.32 mg/vialJanoshik Analytical (CZ)#2161502026-08-24View COA for IP-MOTS10-001 · Full batch record
AOD-96045mg per vialIP-AOD9-00199.537% (RP-HPLC)5.41 mg/vialJanoshik Analytical (CZ)#499382026-08-24View COA for IP-AOD9-001 · Full batch record
GHRP-610mg per vialIP-GHRP6-10-00199.454% (RP-HPLC)10.97 mg/vialJanoshik Analytical (CZ)#726132026-08-24View COA for IP-GHRP6-10-001 · Full batch record
L-Glutathione1500mg per vialIP-GLUT1500-00199.277% (RP-HPLC)1629.23 mg/vialJanoshik Analytical (CZ)#988282026-08-24View COA for IP-GLUT1500-001 · Full batch record
Ipamorelin5mg per vialIP-IPAM5-00199.798% (RP-HPLC)5.45 mg/vialJanoshik Analytical (CZ)#1550932026-08-24View COA for IP-IPAM5-001 · Full batch record
GHK-Cu + BPC-157 + TB-500 + KPV Blend80mg per vialIP-KLOW80-001—GHK-Cu 53.23 mg · BPC-157 11.65 mg · TB-500 11.57 mg · KPV 11.34 mgJanoshik Analytical (CZ)#2144972026-08-24View COA for IP-KLOW80-001 · Full batch record
KPV10mg per vialIP-KPV10-00199.122% (RP-HPLC)12.76 mg/vialJanoshik Analytical (CZ)#1550972026-08-24View COA for IP-KPV10-001 · Full batch record
Selank5mg per vialIP-SELA5-00199.026% (RP-HPLC)5.27 mg/vialJanoshik Analytical (CZ)#1551032026-08-24View COA for IP-SELA5-001 · Full batch record
Semax5mg per vialIP-SEMAX-5-00199.282% (RP-HPLC)5.68 mg/vialJanoshik Analytical (CZ)#1252262026-08-24View COA for IP-SEMAX-5-001 · Full batch record
SS-3110mg per vialSS100-040199.873% (RP-HPLC)10.65 mg/vialJanoshik Analytical (CZ)#1366442026-08-24View COA for SS100-0401 · Full batch record
GLP-2 (TZ)10mg per vialIP-TIRZ10-00199.035% (RP-HPLC)11.14 mg/vialJanoshik Analytical (CZ)#1718902026-08-24View COA for IP-TIRZ10-001 · Full batch record
GLP-2 (TZ)40mg per vialIP-TIRZ40-00199.789% (RP-HPLC)48.52 mg/vialJanoshik Analytical (CZ)#2140392026-08-24View COA for IP-TIRZ40-001 · Full batch record
GLP-1 (SG)5mg per vialIP-SEMA5-00199.789% (RP-HPLC)5.52 mg/vialJanoshik Analytical (CZ)#2140392026-08-24View COA for IP-SEMA5-001 · Full batch record
CJC-1295 + Ipamorelin10mg per vialIP-CJI10-00199.798% (RP-HPLC)10.45 mg/vialJanoshik Analytical (CZ)#1550942026-08-24View COA for IP-CJI10-001 · Full batch record

How verification works

Every vial is labelled with the lot it came from, printed as text and as a barcode. That lot number is the key to its documentation, so what you see is the record for the vial in your hand rather than a generic claim about the product. Published batch records show the laboratory, report date, purity and measured content where reported. Check the certificate for the exact lot: an HPLC purity result does not establish LC-MS identity, sterility or suitability for human or animal use.

Each record carries the laboratory's task ID. The COA itself is published here in full, so what you see is the actual document rather than a claim about it. You can also look up any lot directly on the batch verification page.

Research use only

All materials are supplied for in-vitro laboratory research use only. They are not for human or animal consumption, administration, treatment, diagnostic, cosmetic, food, supplement or veterinary use. Analytical documentation is provided for material identification and quality-control purposes only.

Frequently asked questions

What is on an Index Peptides certificate of analysis?

Check the analytical methods and results actually reported for the lot. HPLC purity, measured content and LC-MS identity are separate checks; a missing result must not be inferred. The record shows the lot number, the testing laboratory, its task ID, the test date and a link to the public verification record.

Why does measured content matter as well as purity?

Purity describes the proportion of the detectable material that is the target compound; it says nothing about how much peptide is in the vial. A vial can be 99% pure and still be substantially underfilled, which is why the measured content per vial is published alongside the purity figure.

Can I check a certificate independently?

Each record names the testing laboratory and report number and links to the published COA. Our batch lookup is a seller-maintained record, not independent authentication by the laboratory. To authenticate a report, use the verification details on the certificate or contact the named laboratory with its report number.

Research use only. Not for human or animal consumption.